Comparison between Ultrasonic Pachymetry and Scheimpflug Based Pentacam for Assessment of Central Corneal Thickness in Myopic Persons of Indian Sikh Origin
Renuka Mahey, Jyotiranjan Mallick, Lily Devi
Ophthalmology Research: An International Journal · pp. 1–8 · Published 31 May 2016
10.9734/OR/2016/26503Abstract
Aims: To compare the central corneal thickness (CCT) measurements between Ultrasound Pachymetry and by the Scheimpflug based Pentacam in myopic persons of Indian Sikh origin. Methodology: In a prospective study, 100 eyes of 50 myopic persons of Indian Sikh origin (aged 16 to 45 years) were subjected to CCT measurement with two methods Ultrasonic Pachymetry and Pentacam HR. Pentacam HR readings were recorded first. CCT readings obtained by both the methods were compared and analysed statistically using unpaired t-test. Results: Mean Pachymetry reading with Ultrasound Pachymeter was 557.9 (SD 9.727) micrometers and with Pentacam was 562.34 (SD 9.91) micrometers. The correlation coefficient (r) between measurements using both instruments was 0.974. There was a tendency of overestimation of CCT measurements with Pentacam with a statistically significant difference between both methods (P<0.001). However, the amount of overestimation seems to be of little clinical importance (4.44 μm). The mean difference was was -4.44 micrometers (95% LOA -0.108 to -8.77 micrometers). Conclusion: 1. CCT measurements obtained with either the non contact Pentacam HR or contact Ultrasonic Pachymeter are close to each other with tendency of obtaining slightly higher readings with Pentacam HR. 2. Pentacam was more convenient to the patient with excellent agreement to the readings by Ultrasonic Pachymeter which is considered the gold standard method of CCT measurement.
References (19)
- 1 Predictive Factors for Open-Angle Glaucoma among Patients with Ocular Hypertension in the European Glaucoma Prevention Study [DOI]
- 2 Central corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinic [DOI]
- 3 The Repeatability of Corneal Thickness Measures [DOI]
- 4 Central corneal thickness and intraocular pressure in a Mongolian population, [DOI]
- 5 Comparison of Central Corneal Thickness Measurements by Rotating Scheimpflug Camera, Ultrasonic Pachymetry, and Scanning-Slit Corneal Topography [DOI]
- 6 Agreement and Repeatability of Central Thickness Measurement in Normal Corneas Using Ultrasound Pachymetry and the OCULUS Pentacam [DOI]
- 7 CENTRAL CORNEAL THICKNESS OF CAUCASIANS AND AFRICAN AMERICANS IN GLAUCOMATOUS AND NON—GLAUCOMATOUS POPULATIONS [DOI]
- 8 Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry [DOI]
- 9 Comparison of Four Corneal Pachymetry Techniques in Corneal Refractive Surgery [DOI]
- 10 Central Corneal Thickness Measurements in Unoperated Eyes and Eyes After PRK For Myopia Using Pentacam, Orbscan II, and Ultrasonic Pachymetry [DOI]
- 11 Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry [DOI]
- 12 Corneal thickness measurements and visual function abnormalities in ocular hypertensive patients [DOI]
- 13 A Comprehensive Comparison of Central Corneal Thickness Measurement [DOI]
- 14 Central Corneal Thickness of Korean Patients with Glaucoma [DOI]
- 15 Central Corneal Thickness in Northwestern American Indians/Alaskan Natives and Comparison with White and African-American Persons [DOI]
- 16 Repeatability and Agreement of 2 Scheimpflug Analyzers in Measuring the Central Corneal Thickness and Anterior Chamber Angle, Volume, and Depth [DOI]
- 17 Repeatability and reproducibility of the BVI ultrasonic Pachymeter [DOI]
- 18 Central Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy.
- 19 Intraocular pressure, goldmann applanation tension, corneal thickness, and corneal curvature in caucasians, asians, hispanics, and african americans [DOI]
Cited by 2
Han Song, Chengyang Liu, Wei Yang · Photodiagnosis and Photodynamic Therapy · 2024
Showing 1 of 2 known citations — external sources report more than can currently be individually listed.
Related research
Article metrics
Real usage data collected on this platform.
48
Page views
0
PDF downloads
6
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.