Skip to content
Research Article Open access CC BY 4.0

Comparative Study on Color Stability of Denture Reline Polymers when Using Microwave and Chemical Disinfection

Farhat Jabeen, Rajeev Gupta, Archana Nagpal, Vishal Katna, Vishwas Mahajan, Pragya Bali

Journal of Advances in Medicine and Medical Research · pp. 1–7 · Published 3 Apr 2019

10.9734/jammr/2019/v29i530085

Abstract

This study investigated the color stability of reline resin after two methods of disinfection i.e  microwave disinfection and chemical disinfection. A stainless steel mold with a breakaway compartment (10 mm in diameter by 0.7 mm thickness) was made to fabricate specimens of various resins. Each material was mixed according to manufacturer’s instructions and applied into the mold. Prior to color stability testing, specimens were cleaned in distilled water for 20 minutes to kill any microorganisms that may had contaminated the discs during fabrication. And then specimens were immersed in Sodium Perborate Monohydrate 200 ml of solution for 15 days and microwaved for 15 days so that it is comparable to chemical disinfection soaking. The color stability of each specimen was measured again using spectrophotometer and values were obtained. The data of ∆E, ∆L, ∆b, ∆a were analysed by 2 way repeated measures ANOVAs test. Significant statistic changes in color parameters ∆L, ∆a, ∆b of the reline resin DPI, Ufi Gel Hard And Kooliner were observed when dentures were disinfected by Sodium Perborate Monohydrate 2% solutions. The color stability of the reline resin was influenced by time, regardless of disinfection or non disinfection. This can be attributed to bleaching (whitening) effect of reline material. Discoloration of resin based materials may be caused by intrinsic or extrinsic factors. Intrinsic factors are related to internal alterations in material resulting from physicochemical reactions or residual monomer oxidation with time. Thus the initiator, quantity and type of monomer and the polymerisation efficiency can affect the color stability of resin based materials. The color stability deviation value ∆E significantly increased to maximum for chemical disinfectant, least for Control group and intermediate for microwaved group. Ufi Gel showed the highest deviation ∆E and Control Group showed the lowest deviation according to results.

Color stability of reline resin microwave disinfection chemical disinfection spectrophotometer dentures sodium perborate.

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.