Performance Analysis of Parabolic Trough Collector in Hot Climate
Adel A. Ghoneim, Adel M. Mohammedein, Kandil M. Kandil
Current Journal of Applied Science and Technology · pp. 2038–2058 · Published 22 Mar 2014
10.9734/BJAST/2014/8772Abstract
In most existing buildings cooling and heating loads lead to high primary energy consumption and, consequently, high CO2 emissions. These can be substantially decreased with suitable energy concepts using appropriate integrated renewable systems. In the present study a numerical model is developed to study the effect of different collector parameters and operating conditions on the performance of parabolic trough solar collector (PTSC) in Kuwait climate. The proposed model takes into consideration the thermal interaction between absorber-envelope, and envelope-envelope for thermal radiation losses which have been neglected in existing models. A review of the equations for convective heat transfer losses was performed as well and new equations were developed and used in the present model. The effects of heat conduction in the collector tube wall and mixed convection in the inner tube, which have been neglected in previous studies, are included in the proposed model. In addition, a case study is carried out adapting parabolic trough collectors to satisfy nominal space heating load, water heating load and cooling load of a typical Kuwaiti dwelling. Finally, the environmental impact of solar heating and cooling systems under Kuwait climate conditions is investigated. Present results indicate that convection loss from the absorber tube to supporting structures is the largest among the other losses (conduction and radiation). Also, at noon time PTSC has the smallest angle of incidence and the highest efficiency and when the annulus between the receiver surface and the glass envelope is In vacuo, conduction and convection across the annulus are effectively eliminated. In addition, space heating load and domestic water heating load can be completely provided by PTSC. The minimum required collector area is about 82 m2 to supply cooling loads of a typical residential house under all climatic conditions in Kuwait. A CO2 emission reduction of about 12.3tonne/year can be achieved as a result of adapting parabolic trough solar collector to a typical Kuwaiti dwelling.
Cited by 4
Sofiane Mihoub, Ali Chermiti, Hani Beltagy · Energy · 2017
Saifullah Zaphar, Dinesh Kumar Saini, Chandrashekara Muniyappa · Journal of Thermal Analysis and Calorimetry · 2025
Abdulmohaimen Adel Abd, Muna S. Kassim · AIP Conference Proceedings · 2023
Prashant Saini, Shweta Singh, Priyanka Kajal · Heliyon · 2023
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
4
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.