Skip to content
Research Article Open access CC BY 3.0

Cell Elasticity-based Microfluidic Label-free Isolation of Metastatic Tumor Cells

Muhymin Islam, Waseem Asghar, Young-tae Kim, Samir M. Iqbal

Journal of Advances in Medicine and Medical Research · pp. 2129–2140 · Published 20 Jan 2014

10.9734/BJMMR/2014/7392

Abstract

Aims: Circulating tumor cells (CTCs) have significant diagnostic value for cancer patients. We report a label-free, simple and rapid microchannel filter type device for isolation of known metastatic cancer cells based on their mechano-physical properties like size and deformability. Study Design: Metastatic renal cancer cells were highly elastic and squeezed through microchannels much smaller than their size. Using a reverse-selectivity approach, the number of microchannels and their dimensions were varied to optimize and reduce the shear stress on tumor cells such that these did not pass through filtering channels. Place and Duration of Study: Department of Electrical Engineering and Department of Bioengineering, University of Texas at Arlington, USA, between June 2012 and March 2013. Methodology: A microfluidic filter type device was fabricated using soft lithography in polydimethylsiloxane (PDMS). The device consistedof one inlet and one outlet connected via 400 microchannels. First of all human derived renal cancer cells were suspended in 1X PBS solution and passed through these microchannels and capture efficiency of the device was calculated. The dimensions of microchannels were varied in order to increase efficiency. Eventually cancer cells were spiked in rat blood and isolated from the mixture. Results: For different dimensions of microchannels capture efficiencies of the devices were calculated. First device consisted of microchannels of 20 µm x 10 µm (Device-1) and the capture efficiency was 31.04±2.5%. Then dimensions were varied to 10 µm x 10 µm (Device-2), 10 µm x 5 µm (Device-3), and 5 µm x 5 µm (Device-4) and capture efficiencies increased to 45.18±1.85%, 70.96±2.39% and 78.36±4.29%, respectively. Rat blood was used as negative control in Device-3 and Device-4 and blood cells were able to pass the microchannels. Finally renal cancer cells were spiked in rat blood and isolated from red blood cells and white blood cells. Conclusion: A novel microdevice is fabricated to detect metastatic renal cancer cells based on their size and deformability. The efficiency of the device is more than 78%. This microfluidic channel device does not require preprocessing of blood (except dilution) or tagging/modification of cells and can be implemented for primary screening of cancer.

Circulating tumor cells (CTCs) microfluidic channels metastasis diagnostics mechano-physical properties

Cited by 22

Microfluidic Sorting of Cells by Viability Based on Differences in Cell Stiffness

Muhymin Islam, Hannah Brink, Syndey Blanche · Scientific Reports · 2017

Showing 11 of 22 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

4

Page views

0

PDF downloads

0

Outbound clicks

22

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.