Laboratory Performance Evaluation of Wantai HIV 1/2 Rapid Test Kit
Ali Johnson Onoja, Manason Rubainu, Ekanem E. Ekanen, Sanni Olaniyi Felix, Segilola Araoye
Asian Journal of Medicine and Health · pp. 24–30 · Published 30 Mar 2022
10.9734/ajmah/2022/v20i430454Abstract
Background: Detection of specific antibodies in the blood/body fluids is the primary testing method for HIV infection. A rapid test is one of the assays used in detecting HIV-specific antibodies. This study was conducted to evaluate the laboratory performance of the Wantai HIV 1/2 Rapid Test Kit. Study Design: Cross-sectional laboratory-based performance characteristics study. Place of Study: The study was conducted across all the six geopolitical zones in Nigeria (North Central, North East, North West, South West, South East, and South-South). Methodology: This study was a cross-sectional laboratory-based performance evaluation with specimens obtained from Nigeria’s six geopolitical zones, characterised in the reference laboratory, and used to evaluate the Wantai test-kit. Ten millilitres of whole blood were collected from all the study sites in EDTA vacutainer tubes through venous puncture from participants, coded, centrifuged, and plasma harvested into cryovials in three aliquots of 2mls each. All specimens were retested using a combination of determine and Unigold rapid test kits. Samples that tested positive or negative concordantly with these kits were used to evaluate the Wantai HIV test kit. The data were entered in Excel and analysed with IBM-SPSS-version 25. Result: Of the 1353 samples, 697 were HIV positive, and 656 were negative. Wantai RTK accurately detected 694(99.6%) positive and 649(98.9%) negative samples. Its sensitivity was 99.57% [95% CI:98.75%-99.91%], and the specificity was 98.93%[95%CI:97.81%-99.57%], with 99.26%[95%CI:98.64%-99.64%] accuracy. Collecting the correct plasma volume was at a 90.0% rate, reading the test result within the time limit, line visibility, interpreting the result, learning the procedure, design of the kit and waste generated were all at the rate of 100.0%. Conclusion: With a sensitivity of 99.6% and a specificity of 98.9%, the Wantai HIV rapid test is suitable for inclusion as a first-line (screening) test in Nigeria’s HIV testing algorithm.
Cited by 0
No indexed citations yet.
Related research
- Trends of HIV/AIDS in Southeast Asia — shares topic coverage
- Accessibility of Children Living with HIV/AIDS to Hospitals in Ten Districts in Indonesia — shares topic coverage
- Knowledge of HIV/AIDS Transmission and Partner Notification Rate among Antenatal Care Attendees in a Tertiary Hospital in Southeast Nigeria — shares topic coverage
- Extrapulmonary Tuberculosis of the Genitourinary System — shares topic coverage
- Family Functioning of People Living with HIV/AIDS Accessing Care at a Nigerian Tertiary Health Centre — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.