Skip to content
Research Article Open access CC BY 3.0

Biodegradation, Bioactivity and In vivo Biocompatibility Analysis of Plasma Electrolytic Oxidized (PEO) Biodegradable Mg Implants

Mehdi Razavi, Mohammad Hossein Fathi, Omid Savabi, Daryoosh Vashaee, Lobat Tayebi

Physical Science International Journal · pp. 708–722 · Published 7 Mar 2014

10.9734/PSIJ/2014/9265

Abstract

In this paper, a plasma electrolytic oxidation (PEO) coating was prepared on AZ91 magnesium (Mg) implant to improve its degradation resistance, bioactivity and biocompatibility. The phase composition and surface morphology of the samples were characterized using X-ray diffraction (XRD) and scanning electron microscope (SEM). The corrosion rate and the bioactivity behavior of the samples were investigated via electrochemical measurements and immersion tests in simulated body fluid (SBF). The biocompatibility of samples was evaluated both in vitro and in vivo. To performed in vitro examinations, L-929 cells were cultured on both coated and uncoated substrates, and for the in vivo study, samples were implanted into the greater trochanter of rabbits as our animal model. The results showed that the PEO coating enhanced the corrosion resistance and in vitro and in vivo biocompatibility of AZ91 Mg implants.    

Plasma electrolytic Oxidation Biodegradable Mg alloy in vitro L-929 cells in vivo Biomedical applications

References (41)

  1. 1 How useful is SBF in predicting in vivo bone bioactivity? [DOI]
  2. 2 Magnesium and its alloys as orthopedic biomaterials: A review [DOI]
  3. 3 In vivo corrosion of four magnesium alloys and the associated bone response [DOI]
  4. 4 Magnesium [DOI]
  5. 5 Biomedical coatings on magnesium alloys – A review [DOI]
  6. 6 The Relationship Between Stress Shielding and Bone Resorption Around Total Hip Stems and the Effects of Flexible Materials [DOI]
  7. 7 Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium [DOI]
  8. 8 Mechanisms of magnesium‐stimulated adhesion of osteoblastic cells to commonly used orthopaedic implants [DOI]
  9. 9 Stress shielding and bone resorption in shoulder arthroplasty [DOI]
  10. 10 A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants [DOI]
  11. 11 Electrodeposition of hydroxyapatite coating on AZ91D magnesium alloy for biomaterial application [DOI]
  12. 12 In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application [DOI]
  13. 13 Anodizing Treatments for Magnesium Alloys and Their Effect on Corrosion Resistance in Various Environments [DOI]
  14. 14 Chemistry and biochemistry of magnesium [DOI]
  15. 15 Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants [DOI]
  16. 16 Magnesium deficiency and osteoporosis: animal and human observations [DOI]
  17. 17 Bonelike Hydroxyapatite Induction by a Gel‐Derived Titania on a Titanium Substrate [DOI]
  18. 18 Magnesium Deficiency: A Cause of Heterogenous Disease in Humans [DOI]
  19. 19 Electrochemical behavior of anodized Mg alloy AZ91D in chloride containing aqueous solution [DOI]
  20. 20 Influence of magnesium substitution on a collagen-apatite biomaterial on the production of a calcifying matrix by human osteoblasts [DOI]
  21. 21 Phosphate coatings on magnesium alloy AM60 part 1: study of the formation and the growth of zinc phosphate films [DOI]
  22. 22 Synthesis and characterization of nano-hydroxyapatite rods/poly(l-lactide acid) composite scaffolds for bone tissue engineering [DOI]
  23. 23 Composition of corrosion layers on a magnesium rare‐earth alloy in simulated body fluids [DOI]
  24. 24 Synthesis and characterization of bioactive forsterite nanopowder [DOI]
  25. 25 Microstructure, mechanical properties and bio-corrosion evaluation of biodegradable AZ91-FA nanocomposites for biomedical applications [DOI]
  26. 26 Characterization of titanium surfaces with calcium and phosphate and osteoblast adhesion [DOI]
  27. 27 Influence of phytic acid concentration on performance of phytic acid conversion coatings on the AZ91D magnesium alloy [DOI]
  28. 28 Fabrication and characterization of magnesium–fluorapatite nanocomposite for biomedical applications [DOI]
  29. 29 Controlling the degradation rate of bioactive magnesium implants by electrophoretic deposition of akermanite coating [DOI]
  30. 30 Design and evaluation of nanophase alumina for orthopaedic/dental applications [DOI]
  31. 31 Preparation of bioactive porous HA/PCL composite scaffolds [DOI]
  32. 32 Ceramic bioactivity: progresses, challenges and perspectives [DOI]
  33. 33 Preparation and property of a novel bone graft composite consisting of rhBMP-2 loaded PLGA microspheres and calcium phosphate cement [DOI]
  34. 34 Bio-corrosion behavior of magnesium-fluorapatite nanocomposite for biomedical applications [DOI]
  35. 35 Nanostructured merwinite bioceramic coating on Mg alloy deposited by electrophoretic deposition [DOI]
  36. 36 Surface modification of magnesium alloy implants by nanostructured bredigite coating [DOI]
  37. 37 Allergy to Metals as a Cause of Orthopedic Implant Failure [DOI]
  38. 38 A REVIEW OF DEGRADATION PROPERTIES OF Mg BASED BIODEGRADABLE IMPLANTS
  39. 39 Long-term effects of plate osteosynthesis: comparison of four different plates [DOI]
  40. 40 Dissolution of powdered human enamel suspended in acid solutions at a high solid/solution ratio under a 5% C02 atmosphere at 20°C [DOI]
  41. 41 Future of Medicine [DOI]

Cited by 79

Nanobiomaterials in periodontal tissue engineering

Mehdi Razavi, Erfan Salahinejad, Mina Fahmy · Nanobiomaterials in Hard Tissue Engineering · 2016

In vivo biocompatibility of Mg implants surface modified by nanostructured merwinite/PEO

Mehdi Razavi, Mohammadhossein Fathi, Omid Savabi · Journal of Materials Science: Materials in Medicine · 2015

In vivo study of nanostructured akermanite/PEO coating on biodegradable magnesium alloy for biomedical applications

Mehdi Razavi, Mohammadhossein Fathi, Omid Savabi · Journal of Biomedical Materials Research Part A · 2014

Porous magnesium-based scaffolds for tissue engineering

Mostafa Yazdimamaghani, Mehdi Razavi, Daryoosh Vashaee · Materials Science and Engineering: C · 2017

Development of electro-co-deposited Ni–Fe(Ti,W)C nanocomposite coatings

S. Khorsand, M. Karbasi, F.S. Sayyedan · Surface Engineering · 2018

In vitro study of nanostructured diopside coating on Mg alloy orthopedic implants

Mehdi Razavi, Mohammadhossein Fathi, Omid Savabi · Materials Science and Engineering: C · 2014

In vivo study of nanostructured diopside (CaMgSi2O6) coating on magnesium alloy as biodegradable orthopedic implants

Mehdi Razavi, Mohammadhossein Fathi, Omid Savabi · Applied Surface Science · 2014

Anticorrosion and Cytocompatibility Assessment of Graphene-Doped Hybrid Silica and Plasma Electrolytic Oxidation Coatings for Biomedical Applications

Juan P. Fernández-Hernán, Antonio J. López, Belén Torres · ACS Biomaterials Science & Engineering · 2021

Showing 20 of 79 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

83

Page views

0

PDF downloads

23

Outbound clicks

79

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.