Research Article Open access CC BY 3.0

Are Biodegradable Third Generation Drug Eluting Stents the Answer to Instent Restenosis?

Amod Amritphale, Nupur Amritphale, Chowdhury H. Ahsan

Cardiology and Angiology: An International Journal · pp. 15–40 · Published 6 Mar 2014

10.9734/CA/2014/9138

Abstract

The third generation biodegradable Drug Eluting Stent (DES) are being evaluated and being introduced in clinical practice. They have been DESigned to overcome limitations associated with durable polymer and a persistent metallic stent scaffold which could be related to late target lesion revascularization (TLR) and very late stent thrombosis (VLST). Although a recent pooled data analysis found that biodegradable polymer stents were superior for TLR and VLST compared with first generation Sirolimus Eluting Stent (SES), superiority has not been demonstrated against second generation Everolimus eluting stents (EES) and is yet to be conclusively proven in randomized trials. This paper reviews the key features, recent trial data, and future directions of the third generation of DES technology including stents with fully biodegradable scaffolds, stents with biodegradable polymer, and polymer free stents.  

Biodegradable coronary stents

References (61)

  1. 1 A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery Disease [DOI]
  2. 2 Incidence, Predictors, and Outcome of Thrombosis After Successful Implantation of Drug-Eluting Stents [DOI]
  3. 3 Pathology of Drug-Eluting Stents in Humans [DOI]
  4. 4 Late Clinical Events After Clopidogrel Discontinuation May Limit the Benefit of Drug-Eluting Stents [DOI]
  5. 5 Guidelines on myocardial revascularization [DOI]
  6. 6 Arterial Remodeling After Coronary Angioplasty [DOI]
  7. 7 A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods [DOI]
  8. 8 Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? [DOI]
  9. 9 Short- Versus Long-Term Duration of Dual-Antiplatelet Therapy After Coronary Stenting [DOI]
  10. 10 A New Strategy for Discontinuation of Dual Antiplatelet Therapy [DOI]
  11. 11 Comparison of coronary bypass surgery with drug-eluting stenting for the treatment of left main and/or three-vessel disease: 3-year follow-up of the SYNTAX trial [DOI]
  12. 12 Evaluation of the Second Generation of a Bioresorbable Everolimus-Eluting Vascular Scaffold for the Treatment of De Novo Coronary Artery Stenosis [DOI]
  13. 13 Heparin plus a glycoprotein IIb/IIIa inhibitor versus bivalirudin monotherapy and paclitaxel-eluting stents versus bare-metal stents in acute myocardial infarction (HORIZONS-AMI): final 3-year results from a multicentre, randomised controlled trial [DOI]
  14. 14 Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials [DOI]
  15. 15 Very Late Coronary Stent Thrombosis of a Newer-Generation Everolimus-Eluting Stent Compared With Early-Generation Drug-Eluting Stents [DOI]
  16. 16 Sirolimus-Eluting Stents Associated With Paradoxic Coronary Vasoconstriction [DOI]
  17. 17 Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial [DOI]
  18. 18 Bioabsorbable Coronary Stents [DOI]
  19. 19 Coronary Stents [DOI]
  20. 20 Effect of Biolimus-Eluting Stents With Biodegradable Polymer vs Bare-Metal Stents on Cardiovascular Events Among Patients With Acute Myocardial Infarction [DOI]
  21. 21 Randomized Comparison of Everolimus- and Paclitaxel-Eluting Stents [DOI]
  22. 22 Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial [DOI]
  23. 23 A Prospective, Randomized Evaluation of a Novel Everolimus-Eluting Coronary Stent [DOI]
  24. 24 Primary Endpoint Results of the EVOLVE Trial [DOI]
  25. 25 2-Year Follow-Up of a Randomized Controlled Trial of Everolimus- and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice [DOI]
  26. 26 Five-Year Clinical and Angiographic Outcomes of a Randomized Comparison of Sirolimus-Eluting and Paclitaxel-Eluting Stents [DOI]
  27. 27 Randomized Trial of a Nonpolymer-Based Rapamycin-Eluting Stent Versus a Polymer-Based Paclitaxel-Eluting Stent for the Reduction of Late Lumen Loss [DOI]
  28. 28 Comparison of Zotarolimus-Eluting Stents With Sirolimus- and Paclitaxel-Eluting Stents for Coronary Revascularization [DOI]
  29. 29 Randomized Comparison of the Nobori Biolimus A9-Eluting Coronary Stent With the Taxus Liberte Paclitaxel-Eluting Coronary Stent in Patients With Stenosis in Native Coronary Arteries [DOI]
  30. 30 Polymer-Free Sirolimus- and Probucol-Eluting Versus New Generation Zotarolimus-Eluting Stents in Coronary Artery Disease [DOI]
  31. 31 Biodegradable Polymer Versus Permanent Polymer Drug-Eluting Stents and Everolimus- Versus Sirolimus-Eluting Stents in Patients With Coronary Artery Disease [DOI]
  32. 32 Circumferential evaluation of the neointima by optical coherence tomography after ABSORB bioresorbable vascular scaffold implantation: Can the scaffold cap the plaque? [DOI]
  33. 33 Three-year results of clinical follow-up after a bioresorbable everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB trial [DOI]
  34. 34 Bioresorbable Scaffold Technologies [DOI]
  35. 35 Two-Year Clinical, Angiographic, and Intravascular Ultrasound Follow-Up of the XIENCE V Everolimus-Eluting Stent in the Treatment of Patients With De Novo Native Coronary Artery Lesions [DOI]
  36. 36 Evaluation in 3 Months Duration of Neointimal Coverage After Zotarolimus-Eluting Stent Implantation by Optical Coherence Tomography [DOI]
  37. 37 2-Year Clinical and Angiographic Outcomes From a Randomized Trial of Polymer-Free Dual Drug-Eluting Stents Versus Polymer-Based Cypher and Endeavor, Drug-Eluting Stents [DOI]
  38. 38 Safety and Efficacy of Biodegradable Polymer-Coated Sirolimus-Eluting Stents in “Real-World” Practice [DOI]
  39. 39 A review of current devices and a look at new technology: drug-eluting stents [DOI]
  40. 40 Randomized evaluation of two drug‐eluting stents with identical metallic platform and biodegradable polymer but different agents (paclitaxel or sirolimus) compared against bare stents: 1‐Year results of the PAINT trial [DOI]
  41. 41 Three-Month Dual Antiplatelet Therapy After Implantation of Zotarolimus-Eluting Stents - The DATE (Duration of Dual Antiplatelet Therapy After Implantation of Endeavor Stent) Registry - [DOI]
  42. 42 Sustained clinical safety and efficacy of a biodegradable‐polymer coated sirolimus‐eluting stent in “real‐world” practice: Three‐year outcomes of the CREATE (multi‐center registry of EXCEL biodegradable polymer drug eluting stents) study [DOI]
  43. 43 Late clinical outcomes after implantation of drug-eluting stents coated with biodegradable polymers: 3-year follow-up of the PAINT randomised trial [DOI]
  44. 44 Newest-generation drug-eluting and bare-metal stents combined with prasugrel-based antiplatelet therapy in large coronary arteries: The BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination part II (BASKET-PROVE II) trial design [DOI]
  45. 45 Bioresorbable polystatin fourth-generation stents [DOI]
  46. 46 TWO-YEAR SUSTAINED EFFICACY OF A NOVEL, POLYMER-FREE SIROLIMUS ELUTING STENT: LATE RESULTS OF THE VESTASYNC II TRIAL [DOI]
  47. 47 Late Complication [DOI]
  48. 48 THE REMEDEE STUDY: INSIGHTS FROM THE ANGIOGRAPHIC AND INTRAVASCULAR ULTRASOUND COMPARISON OF A COMBINATION SIROLIMUS ELUTING EPC CAPTURE STENT WITH A PACLITAXEL ELUTING STENT [DOI]
  49. 49 Bioresorbable Stents [DOI]
  50. 50 TCT-574 Drug-eluting stent with biodegradable polymer in patients with STEMI – short and long term outcomes: data from e-NOBORI and NOBORI 2 trials [DOI]
  51. 51 2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention [DOI]
  52. 52 Coronary-Artery Stents [DOI]
  53. 53 A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial [DOI]
  54. 54 Randomized, Double-Blind, Multicenter Study of the Endeavor Zotarolimus-Eluting Phosphorylcholine-Encapsulated Stent for Treatment of Native Coronary Artery Lesions [DOI]
  55. 55 A Randomized Comparison of the Endeavor Zotarolimus-Eluting Stent Versus the TAXUS Paclitaxel-Eluting Stent in De Novo Native Coronary Lesions [DOI]
  56. 56 Long-Term (>10 Years) Clinical Outcomes of First-in-Human Biodegradable Poly- l -Lactic Acid Coronary Stents [DOI]
  57. 57 Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Trial [DOI]
  58. 58 Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis [DOI]
  59. 59 Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated With Percutaneous Coronary Intervention [DOI]
  60. 60 Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer [DOI]
  61. 61 Second-Generation Drug-Eluting Stents [DOI]

Cited by 2

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

65

Page views

0

PDF downloads

39

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.