Skip to content
Research Article Open access CC BY 4.0

Anterior Migration of the Encircling Band: A Report of Two Cases

Ziya Ayhan, Gül Arıkan, Aylin Yaman, Ismet Durak, A. Osman Saatci

Ophthalmology Research: An International Journal · pp. 80–84 · Published 26 Dec 2014

10.9734/OR/2015/15353

Abstract

Aim: To reiterate the clinical course and management of the cases with anteriorly migrated encircling band.  Report of the Cases: We describe two patients with the migration of a solid silicone encircling band through the insertions of rectus muscles after the successful retinal detachment surgery (cheesewiring phenomenon). While the first patient had also refractory secondary glaucoma and underwent transscleral diode laser photocoagulation several times, the second patient had high myopia with the axial length of 30.06 mm. In both cases, encircling band was cut without further complication. Conclusion: Cheesewiring phenomenon can be rarely seen after buckling procedures and retina specialists should be aware of this rare complication and its possible causes to prevent its happening.  

Cheesewiring retinal surgery scleral buckling scleral buckling complications

References (26)

  1. 1 Retinal Circulatory Changes after Scleral Buckling Procedures [DOI]
  2. 2 EROSION AND INTRUSION OF SILICONE RUBBER SCLERAL BUCKLE [DOI]
  3. 3 Scleral explant removal: the last decade [DOI]
  4. 4 Hypotony caused by scleral buckle erosion in Marfan syndrome [DOI]
  5. 5 The Removal of Scleral Buckles [DOI]
  6. 6 Factors Influencing Retinal Redetachment After Removal of Buckling Elements [DOI]
  7. 7 Removal of scleral explant elements: A 10-year retrospective study [DOI]
  8. 8 LATE SWELLING AND REMOVAL OF MIRAGEL BUCKLES [DOI]
  9. 9 Microbiologic spectrum and susceptibility of isolates in scleral buckle infection in India [DOI]
  10. 10 Erosion of implants in retinal detachment surgery.
  11. 11 BACTERIAL ENDOPHTHALMITIS AFTER RETINAL SURGERY [DOI]
  12. 12 Silicone Sponge Rejection [DOI]
  13. 13 Methicillin-resistant Staphylococcus aureus infections after scleral buckling procedures for retinal detachments associated with atopic dermatitis11The authors have no proprietary interest in any material or device discussed in this article. [DOI]
  14. 14 Migrating scleral explants [DOI]
  15. 15 Subretinal abscess after scleral buckling surgery: a rare risk of retinal surgery [DOI]
  16. 16 Eyelid Fistula Caused by a Scleral Buckle [DOI]
  17. 17 Migration of Solid Silicone Encircling Element Through Four Rectus Muscles [DOI]
  18. 18 An Extruded Encircling Band Straddling the Cornea and Corneal Groove Formation [DOI]
  19. 19 Preserved action of a rectus muscle after transection by an encircling solid silicone band. [DOI]
  20. 20 An Unusual Complication of Retinal Reattachment Surgery [DOI]
  21. 21 Transpalpebral extrusion of solid silicone buckle [DOI]
  22. 22 Clinical Case Notes [DOI]
  23. 23 Total extrusion of a silicone encircling band through the muscle insertions presenting as orbital cellulitis [DOI]
  24. 24 Intracorneal migration of a silicone strap. [DOI]
  25. 25 Sudden Vision Loss Following Retinal Detachment Surgery [DOI]
  26. 26 Reversal of Pupillary Atonia After Removal of an Encircling Band [DOI]

Cited by 2

Doppelbilder 10 Jahre nach skleraler Buckelchirurgie

M. Parlak, A. Yaman, A. O. Saatci · Der Ophthalmologe · 2016

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

61

Page views

0

PDF downloads

15

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.