Analysis of Amantadine Hydrochloride-Phenyl Isothiocyanate Complex in Bulk and Pharmaceutical Dosage Forms by RP HPLC-PDA Method
Sri Kalyani Vemuri, N. Ramya Krishna, M. J. Mohammad, Buchi N. Nalluri
Journal of Pharmaceutical Research International · pp. 278–288 · Published 20 Nov 2013
10.9734/BJPR/2014/6374Abstract
Aim: The aim of the present investigation was to perform the precolumn derivatization of Amantadine Hydrochloride (AMT) with phenylisothiocyanate and to develop a RP-HPLC-PDA method for the quantification of Amantadine Hydrochloride-phenylisothiocyanate (AMT-PITC) complex in bulk and dosage forms which is rapid, sensitive and economical. Study Design: Method development and Validation study. Methodology: A Phenomenex C18 RP column of 250 x 4.6mm dimensions and 5µm particle size with mobile phase containing water and acetonitrile (40:60% v/v) was used at isocratic mode binary pump and eluent was monitored at 273nm. Results & Discussion: The retention time of AMT-PITC complex was 6.3 min. The developed method showed a good linearity in the concentration range of 10-50µg/mL with a correlation coefficient >0.998. The recoveries ranged between 95-105% with a Relative Standard Deviation of (RSD) < 2%. Conclusion: The developed method was validated as per ICH guidelines and successfully used for quantification of AMT by derivatization with PITC. The method was found to be rapid, specific and accurate.
Cited by 2
Paula Santiago‐Díaz, Milagros Rico, Argimiro Rivero · Chemistry & Biodiversity · 2022
Rahul D. Rathod, Vikas R. Patil, Kuldip R. Patil · Asian Journal of Pharmaceutical Analysis · 2022
Related research
- Evaluation of Effective and Safe Extraction Method for Analysis of Polycyclic Aromatic Hydrocarbons in Kolanuts from Côte d’Ivoire — shares topic coverage
- Dissipation Dynamics and Risk Assessment of Imidacloprid in Grape Berries Using LC- MS for Food Safety — shares topic coverage
- Development and Validation of New Analytical Method for the Determination of Particle Size Distribution of Metformin Hydrochloride Using Laser Based Particle Size Analyzer — shares topic coverage
- Development and Validation of Bio Analytical Method for Estimation of Bortezomib in k3 EDTA Human Plasma Using HPLC-ESI-MS/MS and Its Application to a Bioequivalence & CME Studies — shares topic coverage
- Studies on the Persistence of Pyraclostrobin 10% CS in Acidic, Neutral and Basic Waters by Validated HPLC-DAD Method — shares topic coverage
Article metrics
Real usage data collected on this platform.
25
Page views
0
PDF downloads
3
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.