Skip to content
Research Article Open access CC BY 4.0

Alteration of Pulmonary Venous Flow Doppler Post Transcatheter Closure of Atrial Septal Defect

Sara Mohamed Ahmed Gobran, Ayman Mohamed El-Saied, Sahar Abd Allah El-Shedoudy, Dina A. Maria

Cardiology and Angiology: An International Journal · pp. 376–383 · Published 22 Oct 2022

10.9734/ca/2022/v11i4292

Abstract

Background: Atrial septal defect is a common congenital heart anomaly results in hemodynamically significant right ventriclular volume overload and an increase in the pulmonary venous flow. Aim: Evaluate changes of pulmonary venous flow parameters after transcatheter closure of secundum atrial septal defect. Patients and Methods: 50 patients with atrial septal defect aged from 3.5 to 31 years were included in the study. Pulmonary venous flow Doppler and right ventricular function were evaluated before and after successful transcatheter closure by transthoracic and transesophageal echocardiography. Results: The defect size ranged from 15 to 37mm with a mean (24.96 ±7.52), Normal systolic and diastolic waves of pulmonary venous flow Doppler were replaced by a continuous antegrade wave (mean 60±13.6 cm/s) in all atrial septal defect patients. Post-closure, the normal pulmonary venous flow pattern was regained, two separate waves, with a significant decrease in mean peak Systolic wave velocity (44.54±8.12 cm/sec vs 69.61±12.37, P=0.000), the mean peak Diastolic Wave velocity (55.85±9.81 cm/sec vs 72.65±10.38, P=0.000) and a significant increase in the mean peak atrial reversal wave velocity (28.75±4.63cm/sec vs 21.18±3.64, P=0.000). In multivariate regression analysis, significant predictors of haemodynamic significant ASD were ASD size,(odds ratio 1.508, P=0.007, 95% CI 1.153,2.671) and ASD/IAS ratio (odds ratio 2.313, P=0.001, 95% CI 1.064,3.104). Conclusions: Atrial septal defect patients have characteristic pulmonary venous flow pattern: continuous antegrade wave with systolic predominance and decrease in atrial reversal wave, which return to normal after closure. These changes could be helpful echocardiographic tool in prediction of successful closure of the defect.

Atrial Septal Defect Secundum Type (ASDII) Pulmonary Venous Flow (PVF) Pulmonary Artery Pressure (PAP)

References (18)

  1. 1 Guidelines for the Echocardiographic Assessment of Atrial Septal Defect and Patent Foramen Ovale: From the American Society of Echocardiography and Society for Cardiac Angiography and Interventions [DOI]
  2. 2 Atrial Septal Defects – Clinical Manifestations, Echo Assessment, and Intervention [DOI]
  3. 3 Pulmonary venous flow by doppler echocardiography: revisited 12 years later [DOI]
  4. 4 Current concept of transcatheter closure of atrial septal defect in adults [DOI]
  5. 5 State-of-the-Art Atrial Septal Defect Closure Devices for Congenital Heart [DOI]
  6. 6 Usefulness of Doppler tissue imaging analysis of tricuspid annular motion for determination of right ventricular function in normal infants and children [DOI]
  7. 7 Color Doppler Tissue Imaging for Evaluation of Right Ventricular Systolic Function in Patients with Congenital Heart Disease [DOI]
  8. 8 Tricuspid annular plane systolic excursion (TAPSE) can predict the outcome of isolated tricuspid valve surgery in patients with previous cardiac surgery? [DOI]
  9. 9 Effect of acute changes in load on left ventricular diastolic function during device closure of atrial septal defects [DOI]
  10. 10 New pulmonary vein Doppler echocardiographic index predicts significant interatrial shunting in secundum atrial septal defect [DOI]
  11. 11 Role of Transthoracic Doppler Pulmonary Venous Flow Pattern in Large Atrial Septal Defects [DOI]
  12. 12 Immediate Change in Pulmonary Venous Flow Pattern after Deployment of Occluder Device for Atrial Septal Defect [DOI]
  13. 13 How to image individual pulmonary veins with transthoracic echocardiography [DOI]
  14. 14 Echocardiographic Evaluation of Atrial Septal Defect [DOI]
  15. 15 Pulmonary venous flow in large, uncomplicated atrial septal defect [DOI]
  16. 16 Spectral Doppler Interrogation of the Pulmonary Veins in Atrial Septal Defect [DOI]
  17. 17 Altered Pulmonary Venous Flow Pattern in Young Adults with Atrial Septal Defect [DOI]
  18. 18 Device Closure of a Large Atrial Septal Defect in a Patient with Lung Pathology [DOI]

Cited by 2

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

49

Page views

0

PDF downloads

21

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.