Skip to content
Research Article Open access CC BY 4.0

Advantage to Short Circuit Current of Calculation on Power System by the MVA Method

Ming-Jong Lin

Asian Journal of Research in Computer Science · pp. 28–36 · Published 7 Jul 2020

10.9734/ajrcos/2020/v6i130150

Abstract

The short circuit current of the equipment must be carefully calculated. If it is not effective to isolate the fault point, while the system is abnormal. That will leads to prolonged fault time and the instability of power system. The calculation process is very so complicated that must to establish any capacity of equipment on system. This article will introduce method of the traditional algorithm beginning. Next, to establish the basic principles of simplified procedures such as the capacity of two parallel devices are considered as a series method (plus), but the capacity of two series devices are considered as a parallel method to calculate. Finally, to calculate the fault short-circuits current based on the actual equipment capacity on the power system. Another technique is to transform the structure of transmission line from △ to Y so that it easy to simplify for calculation. It is proved to be a simple and easy to understand what method for short circuit fault current of calculation. The method can provide accurate and effective calculation of system short circuit capacity and current at each equipment point, so that designer can make appropriate specifications in design and procurement to avoid wasteful investment.

Single - line diagram per – unit system (P.U.) short circuit current capacity

Cited by 1

A Critical Study on the Protection Coordination System of a 2000kVA - LV Panel 5 of Student Dormitory in located at Al Khoud, Oman

Imadudin Faraj Al Hajri, Suresh Manic Kesavan, Abdulaziz Faraz Obaid Al-Hajri · 2021 International Conference on System, Computation, Automation and Networking (ICSCAN) · 2021

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.