A Survey of SVC Device: Its Principle of Operation, Advantages, and Limitations
Current Journal of Applied Science and Technology · pp. 21–28 · Published 24 Dec 2021
10.9734/cjast/2021/v40i4331615Abstract
This work focuses on the survey of the Static Var Compensator (SVC) device principle of operation, advantages and limitations. There has been persistent problems of blackout and brownout of the power supply in Nigeria and some other developing nation as a result of the high level of instability existing in the power lines. Due to the increase in the population, expansion of the power line network and also load increase, there has been tremendous level of disturbances being introduced into the power lines. These disturbances can cause low-frequency oscillation which may last long and result to instability in the lines if not adequately damped or compensated. SVC is an electrical device and a type of Flexible Alternating Current Transmission Systems (FACTS) device introduced for providing fast-acting reactive power compensation on high voltage electricity transmission networks for voltage regulation and stabilization. However, the SVC device has no revolutionary parts, for the implementation of surge impedance compensation, and it was identified that the device is not suitable to be employed for the regulation of voltage up and downs because it has limited overload capability. The device was designed for power supply line with less load and simple network. Therefore, SVC device cannot provide adequate compensation to the present power supply line because of the huge, complex load and disturbance in the system. This work recommends that the SVC device must be improved or replaced with newer compensation devices in order to achieve better power supply improvement.
Cited by 1
Muhammad Shahzad Nazir, Hayat Ullah, Nauman Ali Larik · International Journal of Ambient Energy · 2024
Related research
- A Modified Optimal Electricity Distribution Algorithm for Nigeria Machine Tools Distribution Zone — shares topic coverage
- Investigation of Field Induced Effect of High Voltage Transmission Line in Calabar South, Nigeria — shares topic coverage
- The Environmental Impact of the Alaoji-Onitsha Transmission Line Project and Resettlement Action Plan — shares topic coverage
- Survey of Encroachment of the Benin-Ughelli Transmission Line Right of Way — shares topic coverage
- Impact of Fault Resistance on Distance Relaying of Ahoada-Yenagoa Transmission Line Using Neplan — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.