A Newly Developed Reverse Phase-High Performance Liquid Chromatography Method for the Assay of Dexmethylphenidate and Serdexmethylphenidate with PDA
Subrahmanyam Talari, V. Anuradha, S. N. Murthy Boddapati, Komala Sai Prathuyasa Ayithabotla
Journal of Pharmaceutical Research International · pp. 203–211 · Published 15 Jun 2021
10.9734/jpri/2021/v33i31B31707Abstract
Aims: The present application is a Newly Validated Reverse Phase-High Performance Liquid Chromatography Method for the Assay of Dexmethylphenidate and Serdexmethylphenidate with PDA. Study design: Mentioned study is a quick, rapid, economical, precise, and accurate reverse phase- high performance liquid chromatographic method for estimating Dexmethylphenidate and Serdexmethylphenidate. Place and duration of study: The present assay was carried out at the Shree icon Pharma laboratories PVT.ltd, Vijayawada, AP, and India, from December 2020 to February 2021. Methodology: The stationary phase Agilent C18 column with dimensions of 150x4.6mm, 3.5 was used for chromatography and pH-2.5 ammonium acetate buffer with orthophosphoric acid: acetonitrile in a 50:50 ratio used as a buffer. The detection wavelength was 265nm, and the flow rate was 1mL/min. The strategy was justified according to ICH guidelines Results: Dexmethylphenidate and Serdexmethylphenidate had retention periods of 4.258 and 5.629 minutes, respectively. For the estimation of Dexmethylphenidate and Serdexmethylphenidate, the method has been validated for linearity, accuracy, precision, stability tests, and forced degradation studies including acid, base, hydrolysis, peroxide, and thermal degradation. By multiplying the quality six times, the system's suitability parameter was investigated, and they were well within reasonable limits. The regression coefficient of the two drugs was found to be 0.999 during the linearity study, which was performed at 10% to 150 percentage points. Precision results for Dexmethylphenidate and Serdexmethylphenidate were 0.54 and 1.24, respectively. The drugs were recovered at a rate of 98-102 percent, which is within the acceptable range. Conclusion: The validation results were found to be satisfactory. It was clear that the proposed method was suitable for routine quality control and analysis of pharmaceutical preparations.
Cited by 3
Jawaharlal Nehru Technological University Anantapur, India, Hathibelagal Mundarinti Sudheer Kumar, Kothapalli Bannoth Chandrasekhar · Methods and Objects of Chemical Analysis · 2022
Khadiga M. Kelani, Ahmed M. W. Nassar, Gamal A. Omran · BMC Chemistry · 2023
A.Raja Reddy, L. Noel Shepherd · International Journal of Innovative Science and Research Technology (IJISRT) · 2024
Related research
- Development or Adaptation of Clinical Guidelines in the Health System of Developing Countries: A Review Article — shares topic coverage
- Development of Pumpkin Pudding-like Food Using Soybeans [Glycine max (L.) Merr.] — shares topic coverage
- Development of a High Value Nutritious Baking Flour from Dried Ripe Banana Peels — shares topic coverage
- A Renewed Understanding of Shell-shape Diversity among Marine Gastropod Species: Invariance and Covariance between Geometrical Parameters in Conispirally Coiled Shells — shares topic coverage
- Growth and Development of Groundnut (Arachis hypogaea L.) as Influenced by Different Levels and Timing of Phosphogypsum Nutrition — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
3
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.