10.9734/OR/2014/12038Abstract
Aim: To assess the accommodative amplitudes of three different foldable acrylic intraocular lenses (IOLs) by measuring with photorefractor Plusoptix CR03 (Plusoptix GmbH, Nuernberg, Germany). Methods: Fifty five pseudophakic eyes of 46 patients (mean age 65.25±10.63 years) were analyzed one month after uneventful phacoemulsification and IOL implantation surgery. Rayner Centerflex (C-Flex) (n=17), AcyrSof MA60BM (n=17), Sensar AR40e (n=21) IOLs were implanted. An objective, dynamic measurement technique with R mode of Plusoptix CR03 device was used to measure accommodation. Accommodation was measured at near distance (0.33m) and far distance (5m). Results: Accommodation amplitudes (mean ± SD) measured with photorefractor at near distance in Rayner, AcyrSof and Sensar groups were 1.45±0.76 diopter (D), 2.82±1.88 D, 2.44±1.02 D, respectively. Accommodative response of AcyrSof and Sensar IOLs was greater than Rayner IOL significantly (p=0.027 and p=0.004, respectively). At far distance, measured accommodation amplitudes in Rayner, AcyrSof and Sensar groups were 1.34±0.54 D, 1.87±0.74 D and 1.74±1.70 D, respectively. There were no significant difference between the groups (p=0.109). Conclusion: The 3-piece hydrophobic acrylic IOLs, AcrySof MA60BM and Sensar AR40e) had a significantly higher accommodative response than the 1-piece plate-haptic hydrophilic acrylic Rayner C-Flex IOL.
References (25)
- 1 Inter‐individual variability in the dynamics of natural accommodation in humans: relation to age and refractive errors. [DOI]
- 2 Laboratory, Clinical, and Kindergarten Test of a New Eccentric Infrared Photorefractor (PowerRefractor) [DOI]
- 3 Apparent Accommodation in Pseudophakic Eyes after Implantation of Posterior Chamber Intraocular Lenses [DOI]
- 4 Apparent accommodation and corneal wavefront aberration in pseudophakic eyes.
- 5 Effect of haptic design on change in axial lens position after cataract surgery [DOI]
- 6 Benefit of against-the-rule astigmatism to uncorrected near acuity [DOI]
- 7 Relationship between apparent accommodation and corneal multifocality in pseudophakic eyes [DOI]
- 8 Repeatability of clinical measurements of the amplitude of accommodation [DOI]
- 9 Continuous measurement of accommodation in human factor applications [DOI]
- 10 Eccentric Photorefraction [DOI]
- 11 Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses: optical analysis.
- 12 Implantation of a New Accommodative Posterior Chamber Intraocular Lens [DOI]
- 13 Apparent accommodation and depth of field in pseudophakia [DOI]
- 14 Theoretical and Measured Pseudophakic Accommodation After Implantation of a New Accommodative Posterior Chamber Intraocular Lens [DOI]
- 15 Small Amounts of Chromatic Aberration Influence Dynamic Accommodation [DOI]
- 16 Measurement of refractive error and accommodation with the photorefractor PowerRef II [DOI]
- 17 Effect of cycloplegia on refractive errors measured with three different refractometers in school-age children [DOI]
- 18 Optics of Photoretinoscopy [DOI]
- 19 Theory of eccentric photorefraction (photoretinoscopy): astigmatic eyes [DOI]
- 20 A comparison of accommodation amplitudes in pseudophakic eyes measured with three different methods [DOI]
- 21 Pseudophakic accommodation with 2 models of foldable intraocular lenses [DOI]
- 22 THE EFFECT OF COGNITIVE DEMAND ON ACCOMMODATION [DOI]
- 23 Screening for refractive errors with the Topcon PR2000 Pediatric Refractometer.
- 24 Accuracy and Precision of the Tomey ViVA Infrared Photorefractor [DOI]
- 25 An integrated system for measuring static and dynamic accommodation with a Canon Autoref R-1 refractometer [DOI]
Cited by 0
No indexed citations yet.
Related research
- Corona Virus Disease (COVID-19) and Other External Factors as Determinants of Accommodation and Restaurant Services in Kenya — shares topic coverage
- Clinical Outcomes of Tetraflex Accommodative Intraocular Lens Implantation 2 Years after Cataract Surgery for Presbyopia — shares topic coverage
- Analysis of Accommodation Gain of Presbyopia Eye After Laser Ablation (or Shrinkage) of Sclera Via Lens Reshaping and Lens Anterior Shift — shares topic coverage
- Principles of Accommodation and Technology Update of Presbyopia Corrections using IR and UV Lasers — shares topic coverage
- Optometric Screening of Elementary Students in Greece — shares topic coverage
Article metrics
Real usage data collected on this platform.
37
Page views
0
PDF downloads
4
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.