Comparative Study of Four-Point Measurements of Copper Thin Films Resistivity in Aligned and Square Configuration at Low Frequencies
Désiré Allassem, B. Mahamout Mahamat, Adoum Kriga, Mahamat Hassan Béchir, Yaya Dagal Dari, Mahamat Ahmat Taha, Yacoub Nassian Nimir, Jean Pierre Chatelon, Jean-Jacques Rousseau
Journal of Engineering Research and Reports · pp. 6–15 · Published 8 Nov 2022
10.9734/jerr/2022/v23i11754Abstract
The main objective of this research work is the comparison of the two Van Der Pauw four-point measurement configurations (aligned and square) commonly used to measure the resistivity of metal thin films which are widely used in the manufacture of planar components such as inductors, transformers, insulators, circulators, etc. Electrical characterization is very important because it ensures the quality of the metal supposed to conduct electrical current in the components mentioned above. The resistivity measured by using the square or aligned configuration sometimes has significant differences. Making a comparative study therefore allow to know which gap between points, which frequencies to choose when measurements must be made by using square or aligned configuration. In this paper, the measured thin films are made of copper which is broadly used in the structures because of its physical, chemical and mechanical properties [1]. The copper is deposited on alumina substrates by magnetron radiofrequency sputtering. Rectangular alumina substrates of dimensions 50mm x 20mm x 635μm were used. Thin film resistivity measurements using a four-point measurement method were performed by using HP 4284A LCRmeter in the frequency range of a few Hz to a few kHz. The comparison was made between the four-point aligned method and the four-point square method based on the frequency, the gap between points and the thin film thickness was made. The results obtained by the study show that both configurations measure the same resistivity up to 1 kHz and then the increase of resistivity in aligned configuration limits its use beyond this frequency. The square configuration can still measure the same resistivity up to 40 kHz. The study also shows that the gap between points is limited to 3 μm in aligned configuration while the square configuration allows a gap up to 5 μm.
Cited by 0
No indexed citations yet.
Related research
- Serum Lead and Micronutrients Levels in Public Transport Drivers in Osogbo, Nigeria — shares topic coverage
- Evaluation of Serum Copper and Zinc Concentrations in Relation to Clinical Status among Adult People Living with HIV/AIDS in North-West Ethiopia — shares topic coverage
- Dietary Intake and Micronutrient Status of School Children in Enugu-South L.G.A., Enugu State, Nigeria — shares topic coverage
- Isolation and Colonial Morphological Characterization of Fungal Species in Copper Laden Sediments of Calancan Bay, Marinduque — shares topic coverage
- Copper, Magnesium and Selenium Levels in Serum Samples of Male Patients with Type 2 Diabetes Mellitus — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.