Skip to content
Research Article Open access CC BY 4.0

Application of Electrical Resistivity Method in Site Characterization along Ado – Afao Road, Southwestern Nigeria

S. O. Ilugbo, A. D. Adebiyi, S. O. Olaogun, T. Egunjobi

Journal of Engineering Research and Reports · pp. 1–16 · Published 20 Jul 2018

10.9734/jerr/2018/v1i49871

Abstract

A geophysical study was carried out at a proposed location for the construction of a structure along Ado-Afao road, Southwestern Nigeria. The aim of the study is to evaluate the electrical properties of the soil for Founding of Engineering structures. The geophysical investigation involved the Vertical Electrical Sounding (VES) technique using the Schlumberger configuration with a total of twenty-one (21) VES within the investigated area. The electrode separation varies from 1 to 100 m. The geoelectric sections identified three to five geoelectric/geologic subsurface layers along the traverses. The topsoil comprising of clay, clayey sand and sandy clay with the resistivity values range from 28 to 800 Ω-m with its thickness varying from 0.4 to 1.9 m. The second layer was found to be lateritic with resistivity ranging between 200 to 800 Ω-m and thickness ranges from 1 to 7.5 m while the weathered layer comprising of clay, clayey sand and sandy clay with resistivity varies from 30 to 220 Ω-m and its thickness varies from 1.2 to 54 m. The fractured basement with resistivity value of 763 Ωm and thickness value of 8m while the fresh basement has a resistivity value ranging from 365 to 2964 Ωm with depth to basement ranging from 8 to 58 m. The resistivity values of the topsoil are indicative of clay, sandy clay and clayey sand. This layer may not be of any special interest since topsoil is normally excavated. Hence, foundation of the proposed structures cannot be found on this layer. Based on the investigation, the subsurface of the study area can be generally classified as incompetent. There is a presence of lateral inhomogeneity of the subsurface layers and geologic features such as fractures and faults. The construction in the area should be founded on the lateritic layer or fresh basement layer coupled with pile foundation to ensure the stability of the building. The choice of foundation material, clay content and topography elevation should be put into consideration.

Geoelectric section overburden thickness isoresistivity maps isopach maps

Cited by 6

MULTI-TECHNIQUES GEOPHYSICAL EVALUATION OF AULE FLOOD PLAIN FOR EARTHLING DEVICE SYSTEM IN SOME PARTS OF AKURE METROPOLIS, SOUTHWESTERN NIGERIA

A. O. Adigun, Bawallah Musa Adesola, Ilugbo Stephen Olubusola · Geosciences Research Journal · 2024

Electrical Resistivity and Geotechnical Attributes and The Dynamics of Foundation Vulnerability

M. Bawallah, S. O. Ilugbo, K. Ozegin · Indonesian Journal of Earth Sciences · 2021

Application of Electrical Resistivity Method to Site Characterisation for Construction Purposes at Institute of Agriculture Research and Training Moor Plantation Ibadan

Babatunde A. Adebo, Oladipupo Emmanuel Makinde, Stephen Olubusola Ilugbo · Indonesian Journal of Earth Sciences · 2021

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

6

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.